The Davis Derby MineWATCH 3 units are powerful programmable monitoring and
control elements based on state of the art 16 bit microprocessor technology with
flexible software to cater for a wide variety of local and remote control and
monitoring applications encountered in coal mines.
The units are certified intrinsically safe to the European CENELEC EN 50
series of standards and are therefore fully approved for use underground in coal
mines in many countries. The MineWATCH 3 is extremely versatile - units
cater for up to 50 programmable timers and 30 programable counters. The
MineWATCH 3 caters for up to 32 line proved digital inputs, 14 analogue inputs,
2 optional 0.4 - 2V analogue outputs, 4 pulser inputs and 12 relay outputs.
Specification
| MineWATCH 3 Outstation Programmable
Monitoring & Control Unit |
| Telemetry Link |
|
BS6556 Parts 1& 2 (FSK) |
| Tranducer Inputs |
Line Proved Digital
0.4 - 2V Analogue
Pulser Inputs
Switched Inputs
Temperature |
32
14
Up to 4
7
Up to 14 |
| Outputs |
IS Relay Outputs
0.4 - 2V Analogue |
Up to 12
2 (optional) |
| Displays |
|
LCAD Character Display
16 LED Status Indicators |
| Additional Features |
Programmable application software featuring:
programmable logic contoller utilising all I/O and the following functions:
50 programmable timers
30 programmable counters
500 links
boolean functions
arithmetic operation
optional local control panel |
Please click here for a .PDF version of