StedFAST Relay Control Units Type 23418 and ICR3
Both types of Relay Control Unit comprise of a sheet steel IP65 rated enclosure
which houses a fused stepdown transformer, relay and terminals. Operation of a
pullkey or a cable fault results in the relay becoming de-energised, opening a
contact that can be used to trip the conveyor or other plant item. A lamp
indicates that the relay is de-energised.
The ICR3 unit can be used as a stop/start station and incorporates a second
relay, stop switch, reset switch and an indicator which glows to indicate the
unit is healthy and that the control relays may be reset to start the conveyor.
Two additional outputs are also provided to allow connection into ancillary
circuits.
The ICR3/P Relay Control Unit can be used as a control station as it
incorporates an integrated PLC unit to provide direct connection of other
conveyor protection devices to the one control unit.
Download the brochure
 |
|
Operation Parameters
|
|
 |
| |
TYPE 23418
24v Pullkey Circuit
2 core diode proved - 200Ω max |
|
| |
TYPE ICR3
15v Pullkey Circuit
2 core diode proved - 230Ω max |
|
| |
TYPE ICR3/P
As ICR3 - additional 5 x 24v
dc user defined digital inputs |
|
| Type 23418 |
|
|
|
Type ICR3 |
|